8715 DP-Calc Micromanometer
8715 DP-Calc Micromanometer

8715 DP-Calc Micromanometer

8715 DP-Calc Micromanometer Specification

  • Resolution
  • 0.1 Pa
  • Protection
  • Compact, robust case
  • Measurement Range
  • -3,735 to +3,735 Pa
  • Equipment Type
  • Micromanometer
  • Humidity %
  • 0 to 95% RH non-condensing
  • Application Media
  • Air
  • Connectivity Type
  • RS-232 serial interface
  • Pressure Range
  • -3,735 Pa to +3,735 Pa
  • Sensor Type
  • Differential Pressure Sensor
  • Temperature Range
  • 0°C to 50°C (32°F to 122°F)
  • Flow Rate
  • With optional probe
  • Material
  • High-impact plastic housing
  • Power Supply
  • 4 x AA alkaline batteries or optional AC adapter
  • Power Consumption
  • Low power consumption (battery life up to 100 hours)
  • Accuracy
  • ±1% of reading ±1 Pa
  • Display Type
  • Digital LCD display
  • Range
  • ±3,735 Pa (±15 in. H2O)
  • Operating Altitude
  • Up to 2,000 m
  • Alarms
  • Audible and visual (configurable)
  • Weight
  • 250 g (8.8 oz) including batteries
  • Units Supported
  • Pa, in. H2O, mm H2O, mbar, psi
  • Mounting
  • Handheld or tripod mountable
  • Backlight
  • Yes, for low light operation
  • Overpressure Protection
  • 10 kPa maximum
  • Compliance
  • CE Marked
  • Data Logging
  • Up to 12,700 samples (with optional logging upgrade)
  • Dimensions
  • 84 x 190 x 44 mm (3.3 x 7.5 x 1.7 in.)
  • Zero Adjustment
  • Auto-zeroing
 
 

More Products in Micromanometer Category

5825 DP-Calc Micromanometer

5825 DP-Calc Micromanometer

Temperature Range : 0°C to 50°C (32°F to 122°F)

Flow Rate : Displays Calculated Airflow (requires optional pitot tube)

Pressure Range : ±3735 Pa

Sensor Type : Piezoelectric Differential Pressure Sensor

Power Consumption : Low Power Consumption

Material : ABS Plastic

5815 DP-Calc Micromanometer

5815 DP-Calc Micromanometer

Temperature Range : 0° to 60°C

Flow Rate : Calculated via optional pitot tube

Pressure Range : 0 to ±3735 Pa

Sensor Type : Differential pressure sensor

Power Consumption : Low power consumption

Material : Highimpact plastic housing

HM675 Hydronic Manometer

HM675 Hydronic Manometer

Temperature Range : 32°F to 122°F (0°C to 50°C)

Flow Rate : Displays Directly (with correct input)

Pressure Range : 60 to +60 psi

Sensor Type : Sensor differential

Power Consumption : Low power consumption

Material : ABS plastic

HM685 Hydronic Manometer

HM685 Hydronic Manometer

Temperature Range : 0°C to 50°C

Flow Rate : Displayed (via Differential Pressure Calculations)

Pressure Range : 0 to ±60.00 kPa

Sensor Type : Differential Pressure Sensor

Power Consumption : Low Power Consumption

Material : ABS Plastic Housing