V8.0 Forward Flow Fest Filter Integrity
V8.0 Forward Flow Fest Filter Integrity

V8.0 Forward Flow Fest Filter Integrity

V8.0 Forward Flow Fest Filter Integrity Specification

  • Frequency
  • 50 Hz
  • Automation Grade
  • Automatic
  • Display Type
  • 7 Touch Screen
  • Number of Specimens
  • 1 sample at a time
  • Measuring Range
  • 0–1000 mL/min; 0–6000 mbar
  • Application
  • Filter membrane and cartridge integrity testing
  • Specimen Size
  • 10–300 mm
  • Interface Type
  • RS232, USB
  • Test Range
  • 0–1000 mL/min
  • Max Height
  • 350 mm
  • Accuracy
  • ±1% Full Scale
  • Response Time
  • ≤ 2 s
  • Power Supply
  • 220V AC ±10%, 50Hz
  • Gas Pressure
  • 0.1~0.6 MPa
  • Operating Voltage
  • 220V/50Hz
  • Port Size
  • 1/4 NPT
  • Humidity
  • 20–90% RH
  • Temperature
  • 10–40°C
  • Equipment Type
  • Forward Flow Filter Integrity Tester
  • Resolution
  • 0.1 mL/min
  • Mounting Type
  • Bench-top
  • Features
  • Data storage, automatic calculation, real-time display, easy operation
  • Usage
  • Laboratory, Industrial
  • Capacity
  • Single sample
  • Machine Weight
  • 12 kg
  • Test Speed
  • Standard
  • Test Width
  • 100 mm
  • Test Stroke
  • 0–300 mm
  • Control Mode
  • Automatic & Manual (Programmable)
  • Test Method
  • Forward flow and bubble point
  • Safety System
  • Emergency stop, over-pressure protection
  • Test Medium
  • Compressed air/nitrogen
  • Memory Capacity
  • Up to 1000 test records
  • Dimensions
  • 400 × 320 × 250 mm
  • Alarm Function
  • Over-pressure, End of test, Error notification
  • Calibration
  • Self-calibration function
  • Data Output
  • Excel & PDF export available
  • Ambient Conditions
  • No vibration, no direct sunlight
  • Language Support
  • Multilingual interface
  • Compliance
  • Meets GMP/GLP standards
 
 

More Products in Filter Integrity Tester Category

V4.0 Full-Automatic Filter Integrity Tester Integtest

V4.0 Full-Automatic Filter Integrity Tester Integtest

Accuracy : ±0.5% F.S.

Max Height : 380 mm

Test Range : 0–9999 mbar

Interface Type : USB, RS232, Ethernet

Specimen Size : Compatible with standard filter sizes

Application : Filter integrity testing for pharmaceutical and laboratory filters

V1.1 Full-Automatic Filter Integrity Tester Integtest

V1.1 Full-Automatic Filter Integrity Tester Integtest

Accuracy : ±0.5% FS

Max Height : 35 cm

Test Range : 0–6000 mbar

Interface Type : USB, Ethernet

Specimen Size : Compatible with standard filter cartridges and capsules

Application : Integrity testing of membrane filters in pharmaceuticals, food & beverage, biological and laboratories

V6.5 Filter Integrity Tester Integtest

V6.5 Filter Integrity Tester Integtest

Accuracy : ±2% F.S.

Max Height : 240 mm

Test Range : 06000 mL/min

Interface Type : USB, RS232, Ethernet

Specimen Size : Various (customizable adapters)

Application : Integrity testing of hydrophilic and hydrophobic membrane filters



Back to top